RCT Global
RCT 0475 Pressure Switch – 1/8" NPT, 1,200kPa Falling Set Point
- SKU
- P-RC-R-7825
- Weight
- 1.5 kg
Specifications
| Manufacturer | RCT Global |
|---|---|
| Product type | AUTO ELECTRICAL |
| SKU | P-RC-R-7825 |
| Weight | 1.5 kg |
Description
RCT 0475 pressure switch, listed with a 1/8" NPT connection and a 1,200kPa falling-pressure set point. The original title says “Dual Circuit”; the family description specifies SPDT switching. Confirm the actual switch configuration before ordering.
- Brand/vendor: RCT Global
- Part number: 0475
- Additional identification recorded: Nason LM-2C-174F/WD148
- Connection: 1/8" NPT, as listed
- Set point for 0475: 1,200kPa falling
Switch-family specifications recorded in the source
- Switch action: SPDT, open and close on falling pressure
- Maximum operating pressure: 14,000kPa
- Proof pressure: 42,000kPa; not an operating-pressure rating
- Current rating: 5A; switching voltage and load category are not specified
- Electrical connection: 3-pin Deutsch DT-series connector
- Diaphragm: Buna N
- IP rating: IP65
Other set-point variants — not the supplied part number
- 4800: 200kPa falling
- 2348: 900kPa falling
- 5236: 1,050kPa falling
- 0475: 1,200kPa falling
Related controller context from the original description
Muirhead Fire Status Panel 5884 is described as monitoring fire-bottle status through two pressure-switch inputs: low-pressure warning and discharge/shutdown. Its recorded controls include key override and a pushbutton for extended shutdown. The source associates the panel with AS5062; this is not a verified compliance claim for this individual switch or an installed fire-suppression system.
Muirhead Idle Timer/Fire Controller 3329 is described as combining engine idle-down and fire-detection shutdown, with a shutdown delay intended to allow parking and engine/turbocharger cooldown. The source also describes a response to fire-suppression pressure loss that prevents normal operation when unsafe levels are detected. These are controller functions, not standalone capabilities of this switch. Neither controller is specified as included.
For a fire-suppression application, have the actual part, set point, contact arrangement, connector pinout and condition checked against the approved system requirements before installation. Do not use family specifications or related-controller descriptions as proof of tested safety performance.