| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||
| Measuring range | 
  | 
||
| Communication interface | IO-Link | ||
| Process connection | threaded connection G 1/2 external thread | 
Application
| Special feature | Gold-plated contacts | 
| Application | for Pt100 and Pt1000 measuring elements | 
Electrical data
| Operating voltage[V] | 18...32 DC; ("supply class 2" to cULus) | 
| Current consumption[mA] | < 50 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time[s] | 1 | 
| Integrated watchdog | yes | 
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | 
Outputs
| Total number of outputs | 2 | 
| Output signal | switching signal; analogue signal; IO-Link; (configurable) | 
| Electrical design | PNP/NPN | 
| Number of digital outputs | 1 | 
| Output function | normally open / normally closed; (parameterisable) | 
| Max. voltage drop switching output DC[V] | 2 | 
| Permanent current rating of switching output DC[mA] | 250 | 
| Number of analogue outputs | 1 | 
| Analogue current output[mA] | 4...20; (response time analogue output: 384 ms) | 
| Max. load[Ω] | (Ub - 10 V) x 50 | 
| Analogue voltage output[V] | 0...10; (response time analogue output: 384 ms) | 
| Min. load resistance[Ω] | 2000 | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | pulsed | 
| Overload protection | yes | 
Measuring/setting range
| Measuring range | 
  | 
||
| Set point SP | 
  | 
||
| Reset point rP | 
  | 
||
| Analogue start point | 
  | 
||
| Analogue end point | 
  | 
||
| In steps of | 
  | 
| Resolution | |
|---|---|
| Resolution of switching output[K] | 0.1 | 
| Resolution of analogue output[K] | 0.1 | 
| Resolution of display[K] | 0.1 | 
Accuracy / deviations
| Switch point accuracy[K] | ± 0,3 | 
| Precision analogue output[K] | ± 0,3 | 
| Display accuracy[K] | ± 0,3 | 
| Temperature drift per 10 K[K] | 0.1 | 
Response times
| Response time[ms] | 130 | 
Interfaces
| Communication interface | IO-Link | 
| Transmission type | COM2 (38,4 kBaud) | 
| IO-Link revision | 1.0 | 
Operating conditions
| Ambient temperature[°C] | -25...70 | 
| Storage temperature[°C] | -40...85 | 
| Protection | IP 67 | 
Tests / approvals
| EMC | 
  | 
||||||||||
| Shock resistance | 
  | 
||||||||||
| Vibration resistance | 
  | 
||||||||||
| MTTF[years] | 207 | 