{"product_id":"xm30pb263p-terasaki-tembreak-1-mccb-3-pole-2-6a-power-switching-circuit-breaker","title":"XM30PB263P Terasaki TemBreak 1 MCCB 3 Pole, 2.6A Power Switching Circuit Breaker","description":"\u003cdiv data-testid=\"specification-table\" class=\"sc-9c010d8e-0 fZGzZd\"\u003e\n\u003ch5 class=\"sc-9c010d8e-1 bsjbxc\"\u003eComponent Type (ETIM Class)\u003c\/h5\u003e\n\u003cdiv class=\"sc-e146ede1-0 sc-9c010d8e-2 ibTHrM izylga\"\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003ePower switching circuit breaker\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"specification-table\" class=\"sc-9c010d8e-0 fZGzZd\"\u003e\n\u003ch5 class=\"sc-9c010d8e-1 bsjbxc\"\u003eElectrical\u003c\/h5\u003e\n\u003cdiv class=\"sc-e146ede1-0 sc-9c010d8e-2 ibTHrM izylga\"\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated current In \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e2.6 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eNumber of poles \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e3\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eMax. rated operation voltage Ue AC\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e525 V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated ultimate short-circuit breaking capacity lcu at 415 V, 50 Hz \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e85 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated service short-circuit breaking capacity lcs at 400 V, 50 Hz \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e85 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eType of protection trip unit \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003eThermal\/magnetic release\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eTrip curve \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003eFixed thermal, fixed magnetic\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eFrame size rating \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e30 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated frequency \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e50-60 Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated insulation voltage Ui \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e690 V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated impulse withstand voltage Uimp \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e8 kV\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eAC power loss per pole at In \u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e2 W\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eElectrical life at Un, In (service cycles)\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e10000 cycles\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NHP","offers":[{"title":"Default Title","offer_id":67250709233968,"sku":"P-XM-N-8714","price":160.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1309\/2917\/files\/IMG-4133_0fd32ac9-2fcb-456b-827e-3382b239a59a.heic?v=1783299394","url":"https:\/\/www.miningsurplus.com.au\/products\/xm30pb263p-terasaki-tembreak-1-mccb-3-pole-2-6a-power-switching-circuit-breaker","provider":"Mining \u0026 Industrial Surplus","version":"1.0","type":"link"}