{"product_id":"terasaki-s160-gj-3-pole-160a-fc-circuit-breaker","title":"Terasaki TemBreak2 S160-GJ 3 POLE 160A FC Circuit Breaker","description":"\u003ch5 class=\"sc-9c010d8e-1 bsjbxc\"\u003eElectrical\u003c\/h5\u003e\n\u003cdiv class=\"sc-e146ede1-0 sc-9c010d8e-2 ibTHrM izylga\"\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated current In\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e160 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eNumber of poles\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e3\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eMax. rated operation voltage Ue AC\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e690 V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated ultimate short-circuit breaking capacity lcu at 415 V, 50 Hz\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e65 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated service short-circuit breaking capacity lcs at 400 V, 50 Hz\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e36 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eType of protection trip unit\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003eThermal\/magnetic release\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eTrip curve\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003eAdj. thermal, adj. magnetic\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eFrame size rating\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e160 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eLong time overload protection adjustment range\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e100-160 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eInstantaneous protection adjustment range\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e960-2080 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated frequency\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e50-60 Hz\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated insulation voltage Ui\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e800 V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eSuitable for isolation\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003eYes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated short circuit breaking capacity, Icu 690V AC\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e7.5 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated short circuit breaking capacity, Ics 690V AC\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e7.5 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eRated impulse withstand voltage Uimp\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e8 kV\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eReverse connection of supply possible\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003eYes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"sc-9c010d8e-3 cTHpEw\"\u003e\n\u003cspan class=\"sc-9c010d8e-4 fYBEjy\"\u003eElectrical life at Un, In (service cycles)\u003c\/span\u003e\u003cspan class=\"sc-9c010d8e-5 eTgkhX\"\u003e20000 cycles\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NHP","offers":[{"title":"Default Title","offer_id":50772143604016,"sku":"P-TE-N-7810","price":450.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1309\/2917\/files\/IMG-0027_6be7199a-607b-4441-811c-dbc1b9c59676.heic?v=1771573856","url":"https:\/\/www.miningsurplus.com.au\/products\/terasaki-s160-gj-3-pole-160a-fc-circuit-breaker","provider":"Mining \u0026 Industrial Surplus","version":"1.0","type":"link"}